Wheatheart Swing Away Flex Auger User Manual
Page 33
W
HEATHEART
- SA F
LEX
A
UGER
3. A
SSEMBLY
71’ - 111’
3.7. T
RUSS
71’–91’
30651 R5
33
4. Pull the long truss cable (2):
• over the cable bridges (7)
• around the cable return bracket (8)
• back over the cable bridges (7)
• back to the cable anchor racket (5)
5. Pull the short truss cable (3):
• over the middle cable bridge (7)
• around the cable return bracket (8)
• back over the middle cable bridge (7)
• back to the cable anchor bracket (5)
Important:
The long truss cable (2) must be installed on the outside of the middle bridge (7).
6. Use loosely attached 5/16” cable clamps to hold the cable in place — 2 cable
clamps per cable bridge and two clamps on the cable return bracket.
Note:
Do not tighten the cable clamps at this time.
7. Place another eyebolt in each weld on tab and thread on a 1/2” locknut a
short way.
8. Thread the end of each truss cable through the appropriate eyebolt and pull
the cable snug. Double-back the cable and secure in place with two 3/8”
cable clamps as in Step 2.
Figure 3.16