Dx-700 remote command list, Output led commands, Scrpwr – Barco DX-700 User Manual
Page 191: Wallcontr, Scrpwr wallcontr, Dx-700 remote, Command list, Sect, Aujtmm=oéãçíé=`згг~ез=iáëí, Lìíéìí=iba=`згг~езл

DX-700 • User’s Guide • Rev 02
191
_K==oÉãçíÉ=`зенкзд=mêçíçÅçä
DX-700 Remote Command List
auJTMM=oÉãçíÉ=`згг~еЗ=iáëí
The following command categories are presented in this section:
•
•
•
•
•
lìíéìí=iba=`згг~еЗл
p`omto
•
Description
: Turn on/off all devices (tile and Fiberlink) connected to the specified
output ID.
•
Set format
: SCRPWR | Bank | Out | Pwr
•
Parameters
:
~
Bank: Bank ID 1 – 3
~
Out: Output ID 1 – 6
~
Pwr: Power mode [ 0 | 1 ] .. 0 = OFF, 1 = ON
S
Example: SCRPWR | 1 | 4 | 1
•
Query format
: SCRPWR? | Bank | Out
•
Query returns
: Pwr | Min | Max
~
Pwr: Power Mode
~
Min: Min Power Mode
~
Max: Max Power Mode
S
Example: SCRPWR? | 2 | 1
1 | 0 | 1
t^ii`lkqo
•
Description
: Set / Query the wall (digital) contrast.
•
Set format
: WALLCONTR | Bank | Out | Contr
•
Parameters
:
~
Bank: Bank ID 1 – 3
~
Out: Output ID 1 – 6
~
Contr: Contrast value [ 0 – Max Contrast ] .. in NIT
Note
Max Contrast can be queried, refer to query format below.
S
Example: WALLCONTR | 1 | 2 | 200