Use the following steps to set the genlock source for the outputs in a bank:
1.
From the Home Menu, press {DX-700 Management}.
2.
Press {Genlock} to display the Bank Sync Menu.
Figure 4-92.
Bank Sync Menu (sample)
Below the menu title, the Source Frame Rate field shows the DX-700’s currently
selected sync source frame rate. This value changes dynamically when you
select different sources and/or frame rates.
3.
In the Sync Source section, select the radio button for the desired genlock
source. Three options are available:
~
If Freerun is selected, the system immediately locks to the DX-700’s
internal timing generator, and the Freerun Rate section is activated.
•
Select a freerun frame rate using the radio buttons in the
Freerun Rate
section (50, 59.94, or 60), or set a custom rate.
•
Please continue with step 6.
~
If Input is selected, focus jumps to one of your input modules.
•
Select an input module and an associated input connector.
•
Please continue with step 4.
~
If Master Sync is selected, the bank locks to the master sync source.
You set this source by pressing {Master} and using the Master Sync
Menu
. Refer to the “
Setting the Master Sync Source
” section on
page 156 for instructions.