beautypg.com

Appendix b – Banner MMD-TA-11B Muting Modules User Manual

Page 49

background image

P/N 116390 rev. C

47

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

MMD-TA-11B / MMD-TA-12B Muting Module

Instruction Manual

Appendix B

E

R

A

B

C

Carrier
Basket

Light

Screen

M1

M3

M2

M4

A ≥ (speed of line ft/sec) x 0.1 sec.
B ≈ 3" or position must hinder
personnel following muted object
C ≤ Length of carrier basket

– Trapping hazards must be avoided and
clearance requirements complied with.
– Switch actuators can not be so long that they
allow a single person to initiate a
muted condition.
– Polarized-retroreflective (with targets
mounted on carrier) and inductive
proximity sensors could be used in a
similar manner, if an individual can
not ride into the hazardous area.

One-way (directional) muting can be used
in "Exit" applications to reduce the
possibility of intentional defeat.

Hard Guarding

Whisker/Limit
Switches

Transfer Line

Figure B-4. Entry/exit system using 4 whisker/limit switches as muting devices

Figure B-5. An entry/exit system using four photoelectric sensors as M1, M2, M3, and M4

R

E

Carrier
Basket

M1

Hard Guarding

M2

M3

M4

Light

Screen

A ≥ (speed of line ft/sec) x 0.1 sec.
B ≈ 3" or position must hinder personnel
following muted object
C ≤ Length of carrier basket
D < (speed of line ft/sec) x 3.0 sec., but beams M1 and M2
must be far enough apart to hinder an individual
from triggering both sensors.

One-way (directional) muting can be used in "Exit" applications to reduce the possibility of intentional defeat.

Safety Mat

D

A

C

B

D