MMD-TA-11B / MMD-TA-12B Muting Module

Instruction Manual

System Installation

+24V dc

A1

+24V dc

0V dc

EDM1

EDM2

OSSD1

OSSD2

0V

0V

MMD-TA-12B

Y5

Y6

Y7

Y8

A2

Y1

Y2

Y3

Y4

+

+

S3

S4

Y3

Y1

13

23

33

Feedback (optional)

Y4

Y2

14

24

34

S1

S2

K2

K1

Machine

Control

MPCE

2

MPCE

1

IM-T-9A

*

*

Figure 3-25. Generic machine interface hookup, model MMD-TA-12B: interface module with two-channel EDM

WARNING . . .

Proper Wiring

The generalized wiring configurations shown are provided only
to illustrate the importance of proper installation. The proper
wiring of the Muting Module to any particular machine is solely the
responsibility of the installer and end user.

CAUTION . . .

Shock Hazard

Always disconnect all power from the Muting Module and the
guarded machine before making any connections or replacing any
component. Use extreme caution to avoid electrical shock at all
times. Serious bodily injury or death could result.

* Installation of transient (arc) suppressors across the coils of MPCE1 and

MPCE2 is recommended (see Warning)

WARNING . . .

Use of Transient Suppressors

Transient suppressors are recommended. They MUST be installed
across the coils of the machine control elements. NEVER install

suppressors directly across the outputs of the Module! It is possible for
suppressors to fail as a short circuit. If installed directly across the contacts of
the Module, a short-circuited suppressor will create an unsafe condition.

WARNING . . .

OSSD Interfacing

To ensure proper

operation, the Muting Module
output parameters and machine
input parameters must be
considered when interfacing the
Muting Module solid-state OSSD
outputs to the machine inputs.

Machine control circuitry must be
designed so that:
• The maximum cable resistance

value between the Muting Module
solid-state safety outputs and the
machine inputs is not exceeded,

• The Muting Module solid-state

safety output maximum
OFF-state voltage does not result
in an ON condition, and

• The Muting Module solid-state

safety output maximum leakage
current, due to the loss of 0V, will
not result in an ON condition.

Failure to properly interface the
OSSD outputs to the guarded
machine could result in serious
bodily injury or death.