Safety & Warnings

Before you begin, read all warnings and installation instructions thoroughly.

Prior to installation, verify all components are a compatible system. Configure and pre-test your LED system prior to permanent installation to ensure all

components are operating correctly. Install in accordance with the NEC and local regulations.

1. Turn OFF 120

~277VAC power at circuit breaker prior to installation.

2. Remove the Input and Output cover ports of the zone receiver with a

#2 Phillips head screwdriver. Connect a compatible constant voltage DC

driver to the receiver. See ‘Wiring Connections’ and the ‘System Diagram.’

3. Connect a compatible RGBW fixture to the receiver. Ensure not to

overload the receiver. In addition, do not exceed the maximum run

length of the fixture. See ‘System Diagram.’

4. Install additional components and accessories. Once complete, turn

circuit breaker ON.

• Install in accordance with the National Electric Code, and local regulations.
• This product is intended to be installed and serviced by a qualified,

licensed electrician.

• Do not connect directly to high voltage 120V~277V power. Install with a

compatible Class 2 constant voltage LED driver (power supply).

• Only install compatible LED drivers and fixtures. Contact technical support

or visit the product page for compatible products.

• This product is rated for indoor installation and is not protected against

moisture.

• Proper heat dissipation will prolong the working lifespan of this product.

Install in a well-ventilated area free from explosive gases and vapors.

• Ensure applicable wire is installed between driver, fixture, and any controls

in between. When choosing wire, factor in voltage drop, amperage

rating, and type (in-wall rated, wet location rated, etc.). Inadequate wire

installation could overhead wires, and cause a fire.

• Do not modify or disassemble this product beyond instructions or the

warranty will be void.

Input Voltage

5VDC Built-in Lithium Battery

Transmitting Distance

99 ft.

Control Type

Pulse Width Modulation (PWM). 4-channel

RGBW fixtures.

Ambient Temperature †

-4°

~ 131°F (-20° ~ 55°C)

Input / Output Voltage

5-24VDC constant voltage

Max Current Load

5A x 4CH Max 20A

Max Output Power

100W/240W/480W (5V/12V/24V)

Ambient Temperature

-22°

~ 131°F (-30° ~ 55°C)

Environment

Indoor / dry location

RGBW Zone Remote

RGBW Zone Receiver

For full specifications, see the ‘Specification Sheet’ available at the online

product page.

• A flashing red indicator light on the zone remote implies a low battery.
• To charge the remote, connect the included USB 2.0A/Mini-B cable to the

remote and to a 5VDC USB port.

• Press the power button on the remote and a blue indicator light will flash

to indicate charging. Once the indicator light turns green, charging is

complete.

• Turn on the remote and the receiver.
• Long press the ‘Learning ID’ button on the receiver until the receiver

beeps. Immediately long press a desired zone on the remote.

• To indicate pairing, the receiver will long beep and a green indicator will

flash 3 times on the remote.

Do not pair multiple remotes to a single receiver or pair multiple receivers to

a single zone. Doing so will cause the system to function improperly. Reset

the remote and receiver to factory settings if improper pairing is performed.

Charging the Remote

Pairing the Remote with a Receiver

Resetting Remote & Receiver to Factory Settings

• To reset the remote, turn on remote and hold Power for three seconds. A

red indicator will flash red 3 times and the remote will be reset.

• To reset a single receiver, long press the ‘Learning ID’ button on the

receiver (you will hear an initial beep). Continue holding for >8 seconds

until the receiver long beeps. The receiver has now been reset to factory

settings.

Installing the Receiver

Installation

Quick Specs

See the online product page for video

tutorials or contact technical support.

Need Additional Assistance?

† Do not install product in an environment outside the listed ambient

temperature. Ensure adequate airflow and heatsinking is considered

when mounting/installing.

WARNING

Shock Hazard. May result in serious injury or death.