Safety & Warnings

Before you begin, read all warnings and installation instructions thoroughly.

Prior to installation, verify all components are a compatible system. Configure and pre-test your LED system prior to permanent installation to ensure all

components are operating correctly. Install in accordance with the NEC and local regulations.

• Install in accordance with the National Electric Code, and local regulations.
• This product is intended to be installed and serviced by a qualified,

licensed electrician.

• Do not connect directly to high voltage 120V~277V power. Install with a

compatible Class 2 constant voltage LED driver (power supply).

• Only install compatible LED drivers and fixtures. Contact technical support

or visit the product page for compatible products.

• This product is rated for indoor installation and is not protected against

moisture.

• Proper heat dissipation will prolong the working lifespan of this product.

Install in a well-ventilated area free from explosive gases and vapors.

• Ensure applicable wire is installed between driver, fixture, and any controls

in between. When choosing wire, factor in voltage drop, amperage

rating, and type (in-wall rated, wet location rated, etc.). Inadequate wire

installation could overhead wires, and cause a fire.

• Do not modify or disassemble this product beyond instructions or the

warranty will be void.

Input / Output Voltage

12-24VDC constant voltage

Control Type

PWM (Pulse Width Modulation).

Compatible with 2-channel K-RANGE

fixtures. Not compatible with 3-channel

K-RANGE fixtures.

Max Current Load

4A x 2CH

Max Output Power

96W/192W (12V/24V)

Ambient Temperature †

-4°

~ 122°F (-20° ~ 50°C)

Environment

Indoor / dry location

For full specifications, see the ‘Specification Sheet’ available at the online

product page.

Installation

Quick Specs

† Do not install product in an environment outside the listed ambient

temperature. Ensure adequate airflow and heatsinking is considered

when mounting/installing.

1. Turn OFF 120-277VAC power at circuit breaker.
2. Determine an accessible location to install a 12-24VDC constant voltage driver (driver voltage must match fixture voltage). Do not install more than one

PWM controller can be attached to a single output of the driver.

3. Pull main power cable through switch box.
a) Attach low voltage load to K-RANGE controller.
b) Attach LED driver to K-RANGE controller. See ‘Wiring Connections’ and Mounting.’
4. Wire LED driver to 120-277VAC power.
5. Pop off K-RANGE faceplate with a flathead screwdriver and attach to switch box. See ‘Mounting.’ Do not remove ribbon cable from controller.
6. Ensure all connections are secure and turn ON 120-277VAC power at circuit breaker.

WARNING

Shock Hazard. May result in serious injury or death.

Turn off power at circuit breaker before installing this product.

Ensure applicable wire is installed between driver, fixture, and any controls in between. When choosing wire, factor in voltage drop, amperage rating, and

type (in-wall rated, wet location rated, etc.). Inadequate wire installation could overhead wires, and cause a fire.