Fixture does not illuminate

• See ‘System Diagram’, ‘Wiring Connections’ and installation guides of

all components. Ensure the system is wired correctly and polarities are

correct.

• Ensure a compatible constant voltage dimmable fixture is installed.

• Ensure the driver and fixture have the same voltage specifications

(12V & 12V, or 24V & 24V).

Fixture does not dim

• Ensure a compatible constant voltage dimmable fixture is installed.

• Ensure a compatible dimming control is installed and wired correctly.

See ‘OMNIDRIVE / Dimmer Control Compatibility List’.

Different fixture types do not dim in sync

• Different fixture types have different circuit designs and may react

differently when dimmed. Ensure each fixture type is installed on a

separate dimmable driver for best performance.

Fixture is quickly flashing or flickering

• Verify a compatible dimming control is installed. If flickering is apparent

at low light levels install a compatible trim-adjustable dimming control.

• Ensure a compatible constant voltage dimmable fixture is installed.

• Ensure different fixture types are not connected to a single driver.

Different fixture types must be connected to individual drivers.

• Ensure all connections are properly secured.

• Ensure fixture is receiving the correct input voltage.

Fixture is slowly flashing

• Ensure driver is not overloaded. An overloaded driver will cause the

internal auto-reset to trip repeatedly.

Installation Trips Main Breaker

• Check wiring for short circuit. If breaker continues to trip there may be

a short in the driver. Call customer support for a replacement driver.

Troubleshooting