beautypg.com

9 dc bus pre-charge, 10 ee rom signals, 11 n-contactor – Rockwell Automation SA3100 Power Module Interface (PMI) Regulator User Manual

Page 32: 12 power supply

background image

2-16

PMI Regulator

2.2.3.9 DC Bus Pre-Charge

The DC bus pre-charge enable signal is used to control the phase advance SCRs in
large AC input units to limit the rate of charge on the bus capacitors. This signal is
also used to close the pre-charge contactor (SCR) when the bus voltage is greater
than the undervoltage threshold level and has reached a steady state.

0V commands the pre-charge to close. +5V commands the pre-charge to open.

2.2.3.10 EE ROM Signals

These signals are used for Power Module parameter storing EE ROM.

2.2.3.11 N-Contactor

PILOT is driven high to pick up an external N-contactor.

2.2.3.12 Power Supply

These voltages are supplied to the PMI Regulator by the gate driver/power supply
board.

Pin 31:

/CHARGE

Pre-charge Enable

Pin 32:

EE_IO

Not Applicable

Pin 33:

EE_SK

Not Applicable

Pin 34:

EE_CS

Not Applicable

Pin 35:

PILOT

Not Applicable

Pin 36:

CVERIFY

Not Applicable

Pin 37:

+5V

Pin 38:

+5V

Pin 39:

+5V

Pin 40:

+15V

Pin 41:

+15V

Pin 42:

-15V

Pin 43:

-15V

Pin 44:

+24V

Pin 45:

ISO_12V

Isolated 12V power supply

Pin 46

I12V_RTN

Isolated 12V power supply return

Pin 49:

+5V

Pin 50:

+5V