Rockwell Automation 2755 Enhanced Decoder Series B User Manual
Page 78
6–5
Configuration: Symbology
Publication 2755-833
Codabar
Field Type Options
Select
No
Yes
Enables/disables decoding of Codabar labels. The default of No
disables decoding of this symbology. Select Yes to enable decoding.
Codabar Specific Lengths
Field Type Options
Edit Numeric 0 through 64 (0)
Sets length checking for Codabar labels. The default is 0, which
means the decoder does not check lengths.
You can specify up to 8 code lengths (maximum of 64 characters).
The code length includes the check character and the start and
stop characters. If you specify a code length other than 0, the
decoder will only decode labels with the number of characters
specified.
Codabar Check Character
Field Type Options
Select
No
Yes
Controls whether the decoder is required to compute and verify a
code check character for Codabar bar codes. The code check
character ensures that the data is read correctly. The default is No,
which means the decoder treats all decoded characters as data.
The Codabar character is computed as a Modulus 16 sum of all
characters value as specified in the AIM specification USS-Codabar.
Include Codabar Check Character
Field Type Options
Select
No
Yes
Controls whether the Codabar check character computed by the
decoder is included in the message sent to the host. The default is
No, which means the Codabar check character is not sent.