beautypg.com

Rockwell Automation 2755 Enhanced Decoder Series B User Manual

Page 243

background image

15–55

ASCII Host Commands

Publication 2755-833

HB - Configure Scanner B Start & Stop Characters

Command Format:

HCsssppp

Function:

Configures Scanner B start and stop characters
for independent host triggering.

Parameters:

sssppp

Command
Parameter

Parameter Function

Valid Values

sss

Start character for Scanner B

ASCII decimal value
000 to 254
255 = None

ppp

Stop character for Scanner B

ASCII decimal value
000 to 254
255 = None

Response:

= rr

rr =

response code

=

end of message control code

Example:

Command:

HB035043

Parameters:

035043

Command
Parameter

Parameter Function

Values

sss

Start character for Scanner B

035 = # character

ppp

Stop character for Scanner B

043 = + character

Response:

= 00CR

00 =

command complete
response code

CR =

end of message control code
for Carriage Return

Implemented in Series B Revision C (and later) decoders.