beautypg.com

Rockwell Automation 2755 Decoded Hand-Held Scanner User Manual

Page 130

background image

E–2

AdaptaScan Pass Through Application

Publication 2755-6.5

The custom cable for the AdaptaScan Pass Through cable connects to the
RS-232 and package detect terminals in the AdaptaScan wiring base.

Transmit (Tx)

No Connection

Receive (Rx)

Clear to Send (CTS)

Ready to Send (RTS)

Shield (SHD)

Custom Cable
Maximum length of
18 inches (.46 meter)

AdaptaScan Wiring Base

PKG DET

+12VDC

Ground

25-Pin

Female DB Connector

No Connection

No Connection

The following table provides the pinout connections for the cable (DB
25-pin female connector).

Pass Through Cable

Pin Number

Function

AdaptaScan Terminal Connection

2

Receive Data Input

Tx (RS-232 Terminal Block)

3

Transmit Data Output

Rx (RS-232 Terminal Block)

4

CTS Input

RTS (RS–232 Terminal Block)

5

RTS Output

CTS (RS-232 Terminal Block)

7

Ground

GND (Package Detect Terminal Block)

9

+V 4.8 to 14.0V DC

12V (Package Detect Terminal Block)

Shield

Shield Ground

SHD (RS-232 Terminal Block)