Load initial configuration values chapter 7 – Rockwell Automation 1771-QDC, D17716.5.85(Passport) MNL. PLASTIC MOLDING MODULE User Manual
Page 76
Enter Your Values Here
Load Initial Configuration Values
Chapter 7
7-7
Worksheet 7ĆB (continued)
Pack Configuration Command Block (PKC)
Control Word ProĆSet 600 Addr. Value
Description
Units
PKC05
N44:121
1000
Minimum ERC PercentageĆĆCavity Pressure
Percent
8
PKC06
N44:122
1000
Minimum ERC PercentageĆĆRam (Screw) Pressure
Percent
8
PKC09
N44:125
*
Output #1 SetĆoutput Value During Profile
Percent Signal Output
4
PKC10
N44:126
*
Output #2 SetĆoutput Value During Profile
Percent Signal Output
4
PKC11
N44:127
*
Output #3 SetĆoutput Value During Profile
Percent Signal Output
4
PKC12
N44:128
*
Output #4 SetĆoutput Value During Profile
Percent Signal Output
4
PKC17
N44:133
0
Output #1 Accel Ramp Rate During Profile
Percent Signal Output per Second
5
PKC18
N44:134
0
Output #2 Accel Ramp Rate During Profile
Percent Signal Output per Second
5
PKC19
N44:135
0
Output #3 Accel Ramp Rate During Profile
Percent Signal Output per Second
5
PKC20
N44:136
0
Output #4 Accel Ramp Rate During Profile
Percent Signal Output per Second
5
PKC25
N44:141
0
Output #1 Decel Ramp Rate During Profile
Percent Signal Output per Second
5
PKC26
N44:142
0
Output #2 Decel Ramp Rate During Profile
Percent Signal Output per Second
5
PKC27
N44:143
0
Output #3 Decel Ramp Rate During Profile
Percent Signal Output per Second
5
PKC28
N44:144
0
Output #4 Decel Ramp Rate During Profile
Percent Signal Output per Second
5
PKC41
N44:157
0
Ram (screw) Pressure Minimum Control Limit
Pressure
3
PKC42
N44:158
*
Ram (screw) Pressure Maximum Control Limit
Pressure
3
PKC43
N44:159
*
Selected Ram (screw) Pressure Valve, Output for Minimum Percent Signal Output
4
PKC44
N44:160
*
Selected Ram (screw) Pressure Valve, Output for Maximum Percent Signal Output
4
PKC45
N44:161
0
Cavity Pressure Minimum Control Limit
Pressure
1
PKC46
N44:162
*
Cavity Pressure Maximum Control Limit
Pressure
1
PKC47
N44:163
*
Selected Cavity Pressure Valve, Output for Minimum
Percent Signal Output
4
PKC48
N44:164
*
Selected Cavity Pressure Valve, Output for Maximum
Percent Signal Output
4
PKC49
N44:165
100
Proportional Gain for Ram (screw) Pressure Control
None
PKC50
N44:166
400
Integral Gain for Ram (screw) Pressure Control
Inverse Time (Algorithm)
6
PKC51
N44:167
0
Derivative Gain for Ram (screw) Pressure Control
Time (Algorithm)
7
PKC52
N44:168
100
Proportional Gain for Cavity Pressure Control
None
PKC53
N44:169
400
Integral Gain for Cavity Pressure Control
Inverse Time (Algorithm)
6
PKC54
N44:170
0
Derivative Gain for Cavity Pressure Control
Time (Algorithm)
7
PKC57
N44:173
0
Profile High Ram (screw) Pressure Alarm Setpoint
Pressure
3
PKC58
N44:174
0
Profile High Cavity Pressure Alarm Setpoint
Pressure
1
1
Pressure
2
Velocity along Axis
3
Pressure
4
Percent Signal Output
00000 to 20000 PSI
00.00 to 99.99 inches per second
0000 to 9999 PSI
00.00 to 99.99
0000.0 to 2000.0 Bar
000.0 to 999.9 millimeters per second
000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse Time (Algorithm)
7
Time (Algorithm)
8
Percent
0000 to 9999
00.00 to 99.99 minutes (ISA)
00.00 to 99.99 minutes (ISA)
00.00 to 99.99
00.00 to 99.99 seconds (AĆB)
00.00 to 99.99 seconds (AĆB)
* Refer to the appropriate section later in this chapter for information on this parameter