Enter Your Values Here

Load Initial Configuration Values

Chapter 7

7-7

Worksheet 7ĆB (continued)
Pack Configuration Command Block (PKC)

Control Word ProĆSet 600 Addr. Value

Description

Units

PKC05

N44:121

1000

Minimum ERC PercentageĆĆCavity Pressure

Percent

8

PKC06

N44:122

1000

Minimum ERC PercentageĆĆRam (Screw) Pressure

Percent

8

PKC09

N44:125

*

Output #1 SetĆoutput Value During Profile

Percent Signal Output

4

PKC10

N44:126

*

Output #2 SetĆoutput Value During Profile

Percent Signal Output

4

PKC11

N44:127

*

Output #3 SetĆoutput Value During Profile

Percent Signal Output

4

PKC12

N44:128

*

Output #4 SetĆoutput Value During Profile

Percent Signal Output

4

PKC17

N44:133

0

Output #1 Accel Ramp Rate During Profile

Percent Signal Output per Second

5

PKC18

N44:134

0

Output #2 Accel Ramp Rate During Profile

Percent Signal Output per Second

5

PKC19

N44:135

0

Output #3 Accel Ramp Rate During Profile

Percent Signal Output per Second

5

PKC20

N44:136

0

Output #4 Accel Ramp Rate During Profile

Percent Signal Output per Second

5

PKC25

N44:141

0

Output #1 Decel Ramp Rate During Profile

Percent Signal Output per Second

5

PKC26

N44:142

0

Output #2 Decel Ramp Rate During Profile

Percent Signal Output per Second

5

PKC27

N44:143

0

Output #3 Decel Ramp Rate During Profile

Percent Signal Output per Second

5

PKC28

N44:144

0

Output #4 Decel Ramp Rate During Profile

Percent Signal Output per Second

5

PKC41

N44:157

0

Ram (screw) Pressure Minimum Control Limit

Pressure

3

PKC42

N44:158

*

Ram (screw) Pressure Maximum Control Limit

Pressure

3

PKC43

N44:159

*

Selected Ram (screw) Pressure Valve, Output for Minimum Percent Signal Output

4

PKC44

N44:160

*

Selected Ram (screw) Pressure Valve, Output for Maximum Percent Signal Output

4

PKC45

N44:161

0

Cavity Pressure Minimum Control Limit

Pressure

1

PKC46

N44:162

*

Cavity Pressure Maximum Control Limit

Pressure

1

PKC47

N44:163

*

Selected Cavity Pressure Valve, Output for Minimum

Percent Signal Output

4

PKC48

N44:164

*

Selected Cavity Pressure Valve, Output for Maximum

Percent Signal Output

4

PKC49

N44:165

100

Proportional Gain for Ram (screw) Pressure Control

None

PKC50

N44:166

400

Integral Gain for Ram (screw) Pressure Control

Inverse Time (Algorithm)

6

PKC51

N44:167

0

Derivative Gain for Ram (screw) Pressure Control

Time (Algorithm)

7

PKC52

N44:168

100

Proportional Gain for Cavity Pressure Control

None

PKC53

N44:169

400

Integral Gain for Cavity Pressure Control

Inverse Time (Algorithm)

6

PKC54

N44:170

0

Derivative Gain for Cavity Pressure Control

Time (Algorithm)

7

PKC57

N44:173

0

Profile High Ram (screw) Pressure Alarm Setpoint

Pressure

3

PKC58

N44:174

0

Profile High Cavity Pressure Alarm Setpoint

Pressure

1

1

Pressure

2

Velocity along Axis

3

Pressure

4

Percent Signal Output

00000 to 20000 PSI

00.00 to 99.99 inches per second

0000 to 9999 PSI

00.00 to 99.99

0000.0 to 2000.0 Bar

000.0 to 999.9 millimeters per second

000.0 to 999.9 Bar

5

Percent Signal Output per Second

6

Inverse Time (Algorithm)

7

Time (Algorithm)

8

Percent

0000 to 9999

00.00 to 99.99 minutes (ISA)

00.00 to 99.99 minutes (ISA)

00.00 to 99.99

00.00 to 99.99 seconds (AĆB)

00.00 to 99.99 seconds (AĆB)

* Refer to the appropriate section later in this chapter for information on this parameter