Enter Your Initial Values Here
Jog Your Machine
Chapter 5
5-3
Worksheet 5. A
Ram (screw) Jog Configuration Values
Control Block
Word
ProĆSet 600
Address
Value
Description
Units
Inject, Forward Jog
JGC17
N40:73
Set Output Values Output #1
% Signal Output
1
JGC18
N40:74
Output #2
% Signal Output
1
JGC19
N40:75
Output #3
% Signal Output
1
JGC20
N40:76
Output #4
% Signal Output
1
Inject, Reverse Jog
JGC25
N40:81
Set Output Values Output #1
% Signal Output
1
JGC26
N40:82
Output #2
% Signal Output
1
JGC27
N40:83
Output #3
% Signal Output
1
JGC28
N40:84
Output #4
% Signal Output
1
Screw Rotate Jog
JGC09
N40:65
Set Output Values Output #1
% Signal Output
1
JGC10
N40:66
Output #2
% Signal Output
1
JGC11
N40:67
Output #3
% Signal Output
1
JGC12
N40:68
Output #4
% Signal Output
1
Jog RPM and Pressure Alarms
JGC05
N40:61
ScrewĆrotate Jog RPM, Alarm Setpoint Rotational Speed
3
JGC06
N40:62
Screw Jog Pressure, Alarm Setpoint
Ram (screw) Pressure
2
1
% Signal Output
2
Pressure
3
Rotational Speed
00.00 to 99.99 %
0000 to 9999 PSI
000.0 to 999.9 RPM
000.0 to 999.9 Bar
ATTENTION: You can connect up to four different valves to
your QDC module. Although all four may not directly jog the
ram (screw), consider their indirect effect when setting jog
set-output values. Indirectly, they could cause unexpected
machine motion with possible damage to equipment or injury to
personnel.