Rockwell Automation 1771-QDC, D17716.5.85(Passport) MNL. PLASTIC MOLDING MODULE User Manual
Page 189
HPC Block Identifier
Profile Algorithm
02=Hold 00=Pack
0=Ram Press vs Time
1=Cav Press vs Time
Hold/PreĆdecompression
Logical Bridging
0=Start Movement
1=Stop and set outputs
PreĆdecompression/Plastication
Logical Bridging
0=Start Plastication
1=Stop and set outputs
Profile Offset Sign
1=Negative 0=Positive
12=Pack Cav/Press
13=Pack Ram/Press
14=Hold Cav/Press
15=Hold Ram/Press
Open/Closed Loop
1=Open 0=Closed
Enable/Disable ERC
1=Off 0=On
00=Pack Ram Press vs Time
01=Pack Cav Press vs Time
02=Hold Ram Press vs Time
03=Hold Cav Press vs Time
08=Pack Ram Press vs Time
09=Pack Cav Press vs Time
10=Hold Ram Press vs Time
11=Hold Cav Press vs Time
Code:
Your value
Required initial value
loaded by ProĆSet 600
0 or 1
Blank Worksheets
Appendix A
A-20
Worksheet 8ĆB
Pack/Hold Profile Block (HPC)
Control Word HPC01ĆBxx
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
ProĆSet 600 Addr. B38/bit
271 270 269 268 267 266 265 264 263 262 261 260 259 258 257 256
Value
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
0
Control Word HPC03ĆBxx
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
ProĆSet 600 Addr. B38/bit
303 302 301 300 299 298 297 296 295 294 293 292 291 290 289 288
Value
0
0
0
0
0
0
1
1
0
0
0
0
0
0
0
0
Control Word HPC04ĆBxx
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
ProĆSet 600 Addr. B38/bit
319 318 317 316 315 314 313 312 311 310 309 308 307 306 305 304
Value
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1