Configure the qdc module's i/o chapter 3 – Rockwell Automation 1771-QDC, D17716.5.85(Passport) MNL. PLASTIC MOLDING MODULE User Manual
Page 41
Enter Your Final Values Here
Configure the QDC Module's I/O
Chapter 3
3-10
Worksheet 3ĆE
Final SensorĆconfiguration Values
Input
Line Control
Word
ProĆSet 600
Address
Value
Description
Units
1
1
MCC09
N40:5
0
Minimum Screw Position
Screw Axis Measured from zero
1
2
MCC10
N40:6
Maximum Screw Position
Screw Axis Measured from zero
1
3
MCC11
N40:7
Analog Signal @ Min Screw Position
Input Signal Range
2
4
MCC12
N40:8
Analog Signal @ Max Screw Position
Input Signal Range
2
2
5
MCC17
N40:13
0
Minimum Screw Pressure
Screw Pressure
3
6
MCC18
N40:14
Maximum Screw Pressure
Screw Pressure
3
7
MCC19
N40:15
Analog Signal @ Min Screw Pressure
Input Signal Range
2
8
MCC20
N40:16
Analog Signal @ Max Screw Pressure
Input Signal Range
2
3
9
MCC51
N40:47
0
Minimum Screw RPM
Rotational Speed
4
10 MCC52
N40:48
Maximum Screw RPM
Rotational Speed
4
11
MCC53
N40:49
Analog Signal @ Min Screw RPM
Input Signal Range
2
12 MCC54
N40.50
Analog Signal @ Max Screw RPM
Input Signal Range
2
4
13 MCC57
N40:53
0
Minimum Cavity Pressure
Cavity Pressure
5
14 MCC58
N40:54
Maximum Cavity Pressure
Cavity Pressure
5
15 MCC59
N40:55
Analog Signal @ Min Cavity Pressure
Input Signal Range
2
16 MCC60
N40:56
Analog Signal @ Max Cavity Pressure
Input Signal Range
2
1
Incremental Distance
2
Input Signal Range
3
Pressure
00.00 to 99.99in
00.00 to 10.00VDC or
0000 to 9999 PSI
000.0 to 999.9mm
01.00 to 05.00VDC or
000.0 to 999.9 Bar
04.00 to 20.00MADC
4
Rotational Speed
5
Pressure
000.0 to 999.9 RPM
00000 to 20,000 PSI
0000.0 to 2000.0 Bar