Figure 4.2 – menu structure hierarchy, Programming 4-3 – Rockwell Automation 1560E SMC Flex Smart Motor Controller User Manual
Page 83

Programming
4-3
1560E-UM050B-EN-P - June 2013
Parameter
Motor
Set Up
Utility
Linear List
Protection
Parameter
Monitoring
Communications
uw
v
Esc
Parameter
Motor
Set Up
Utility
Linear List
Protection
Parameter
Monitoring
Communications
uw
v
Esc
Esc
Metering
Basic
Overload
Jam
Comm Masks
Language
Linear List
Volts Phase A-B
SMC Option
Overload Class
Jam F Lvl
Logic Mask
Language
All parameters
Volts Phase B-C
Motor Connection
Service Factor
Jam F Dly
Parameter Mgt x
Parameter Mgt x
Parameter Mgt. x
Volts Phase C-A
Line Voltage
Motor FLC
Jam A Lvl
Current Phase A
MV Ratio
Overload Reset
Jam A Dly
Current Phase B
Starting Mode
Overload A Lvl
Parameter Mgt x
Data Links
Motor Data
Current Phase C
Ramp Time
Parameter Mgt x
Data In A1
Motor Flc
Watt Meter
Initial Torque
Data In A2
Motor ID
Megawatt Hours
Cur Limit Lvl
Stall
Data In B1
CT Ratio
Elapsed Time
Kickstart Time
Underload
Stall Dly
Data In B2
MV Ratio
Meter Reset
Kickstart Lvl
Underload F Lvl
Parameter Mgt x
Data In C1
Parameter Mgt x
Power Factor
Option 2 Input
Underload F Dly
Data In C2
Mtr Therm Usage
Stop Mode
Underload A Lvl
Data In D1
Stop Time
Underload A Dly
Ground Fault
Data In D2
Braking Current
Parameter Mgt x
Gnd Flt Enable
Data Out A1
Overload Class
Gnd Flt Lvl
Data Out A2
Service Factor
Gnd Flt Dly
Data Out B1
Motor FLC
Undervoltage
Gnd Flt Inh Time
Data Out B2
CT Ratio
Undervolt F Lvl
Gnd Flt A Enable
Data Out C1
Overload Reset
Undervolt F Dly
Gnd Flt A Lvl
Data Out C2
Aux1 Config
Undervolt A Lvl
Gnd Flt A Dly
Data Out D1
Fault Contact
Undervolt A Dly
Parameter Mgt x
Data Out D2
Alarm Contact
Parameter Mgt x
Parameter Mgt x
Aux2 Config
Backspin Timer
PTC
Parameter Mgt x
Overvoltage
PTC Enable
Overvolt F Lvl
Parameter Mgt x
Dual Ramp (Option 2
Input = Dual Ramp)
Overvolt F Dly
Starting Mode 2
Overvolt A Lvl
Ramp Time 2
Overvolt A Dly
Phase Reversal
Initial Torque 2
Parameter Mgt x
Phase Reversal
Cur Limit Lvl 2
Parameter Mgt x
Kickstart Time 2
Kickstart Lvl 2
Parameter Mgt x
Unbalance
Restart
Unbalance F Lvl
Starts Per Hour
Preset SS (Option 2
Unbalance F Dly
Restart Attempts
Input = Preset SS)
Unbalance A Lvl
Restart Dly
Slow Speed Sel
Unbalance A Dly
Parameter Mgt x
Slow Speed Dir
Parameter Mgt x
Slow Speed Acc
Slow Running Cur
Parameter Mgt x
(Option 2 Input =
Accu-Stop)
Braking Current
Slow Speed Sel
Slow Speed Dir
Slow Accel Cur
Slow Running Cu
Stopping Current
Parameter Mgt x
Figure 4.2 – Menu Structure Hierarchy
u
Depending upon SMC option selected, some parameters may not appear in product display.
v
Steps back one level.
w
For further information on parameters, see Appendix B.
x
For further information on parameter management, see page 4-7.