SMC-Flex Bit Identification
Table 8.G – Logic Status Word
Bit #
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
Status
Description
X
Enabled 1 – Control Power Applied
0 – No Control Power
X
Running 1 – Power Applied to Motor
0 – Power not Applied to Motor
X
Phasing 1 – ABC Phasing
0 – CBA Phasing
X
Phasing
Active
1 – 3-phase is valid
0 – No valid 3-phase is detected
X
Starting
(Accel)
1 – Performing a Start Maneuver
0 – Not performing a Start Maneuver
X
Stopping
(Decel)
1 – Performing a Stop Maneuver
0 – Not performing a Stop Maneuver
X
Alarm
1 – Alarm Present
0 – No Alarm Present
X
Fault
1 – Fault Condition Exists
0 – No Fault Condition
X
At Speed 1 – Full Voltage Applied
0 – Not Full Voltage Applied
X
Start/
Isolation
1 – Start/Isolation Contactor Enabled
0 – Start/Isolation Contactor Disabled
X
Bypass
1 – Bypass Contactor Enabled
0 – Bypass Contactor Disabled
X
Ready
1 – Ready
0 – Not Ready
—
—
Bits 12 to 15 – Not Used
Table 8.H – Logic Command Word
Bit #
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
Status
Description
X
Stop
1 – Stop/Inhibit
0 – No Action
X
Start
1 – Start
0 – No Action
X
Option #1
Input
1 – Stop Maneuver/Inhibit
0 – No Action
X
Clear
Faults
1 – Clear Faults
0 – No Action
X
Option #2
Input
1 – Perform Option 2 function
0 – No Action
—
—
Bits 5 to 15 – Not Used