Human interface module (cont.) – Rockwell Automation 1560E SMC Flex Smart Motor Controller User Manual
Page 100

6-2
Optio
1560E-UM050B-EN-P - June 2013
Human Interface Module
(cont.)
Option
Action
Operation
Pump Control
II
The green start button, when pressed, will
commence motor acceleration to full speed.
O
O
The red stop button, when pressed, will
provide a coast stop, and/or reset a fault.
Pump Control
Jog
Jog
The jog button, when pressed, will initiate a
pump stop maneuver.
Braking Control
Ê
II
The green start button, when pressed, will
commence motor acceleration to full speed.
O
O
The red stop button, when pressed, will
provide a coast stop, and/or reset a fault.
Smart Motor Braking
Jog
Jog
The jog button, when pressed, will initiate a
brake stop.
II
The green start button, when pressed, will
commence motor acceleration to full speed.
O
O
The red stop button, when pressed, will
provide a coast stop, and/or reset a fault.
Accu-Stop
Jog
Jog
With a “stopped” status, the jog button, when
pressed, will initiate slow speed motor
operation. From an “at speed” condition, the
jog button, when pressed, will initiate braking
to slow speed operation. The controller will
maintain slow speed operation as long as the
jog button is pressed.
II
The green start button, when pressed, will
commence motor acceleration to full speed.
O
O
The red stop button, when pressed, will
provide a coast stop, and/or reset a fault.
Slow Speed
with Braking
Jog
Jog
The jog button will initiate a brake stop.
* Slow Speed cannot be operated via the
HIM.
Ê
Braking Control is not offered for standard use in MV applications. Please consult factory for further
assistance.
The Bulletin 20-HIM interface module’s stop push
button is not intended to be used as an emergency stop.
Refer to the applicable standards for emergency stop
requirements.
A T T E N T I O N