P:\INSTALLATION INST\Mechanical Hardware\INST-S6200.vsd Rev -

01-11 Page 3

STEP 1: PREPARE DOOR

1. Mark position of holes on the door per template (see figure 1).

2. Drill all holes marked on the door for the device chassis and top and bottom latch mounting
brackets.

3. Mortise hole for outside trim is required.

NOTE; Any hole drilled from the outside, first needs a pilot hole drilled from the inside

to ensure good alignment.

Figure 1

2-7/16”

Mark Backset

JAMB

2-5/16"

3-7/32"

INSIDE FACE OF DOOR

1016mm

(40")

Mark of device

CL

3-7/32"

1-15/32"

1/4”

of top and bottom latches

CL

Surface of the door must be
flush. Clear away any raised
jutting to allow the exit device to
rest on flat surface of the door.

40" to finished floor

Standard centerline height of device is 40" above the finished floor.

Prepare door for your specific
device per supplied template.