The EntryCheck™ 921P Indoor/Outdoor Keypad is a surface mount digital
keyless entry system designed for access control applications. The backlit
keys are bright and, easy-to-read. A heavy cast vandal resistant housing
design with mounting plate allows the 921P to be mounted on a rugged
surface or on a standard single-gang electrical box. The control electronics
are housed in a separate enclosure for added security. This helps to
prevent unauthorized access to the electronics of the keypad.
The 921P has a capacity of 500 users. Users can be assigned to use 4 to 6
digit PIN codes and or access cards. An authenticated access can be
programmed to activate one, or both of the relay outputs.
The timed “anti-passback” feature prevents using the same credentials
twice before a programmed waiting period has elapsed.
Two long lasting solid state LED indicators show the status of the system.
The left bi-color indicator lights red to indicate power, then green when a
relay is active (e.g., an access grant, etc.). The right indicator flashes
yellow to indicate that the keypad is in programming mode.
An internal sounder can be programmed to beep each time a key is
pressed or when an output is activated. An internal jumper sets the
sounder volume high or low
The SENSE input can be configured two ways through programming .
When configured for “Door Sense”, the input is wired to a normally closed
door position switch to detect when the door is opened or closed. Forced
entry or door ajar situations can then be detected. The “Auto-relock” feature
can also be used to turn off the Main Relay output immediately when the
door is closed after access has been granted to prevent “tailgating”.
When the SENSE input is configured for “Inhibit”, the input can be wired to
a normally open “service” switch or automatic timer that will disable access
while the switch is closed.
The REQUEST-TO-EXIT input can be wired to a normally open pushbutton
to provide codeless activation of the Main Relay, Auxiliary Relay, Output #3
or Output #4 (programmable).
The ALARM SHUNT signal is available when access is granted. This
signal can be programmed to activate any of the relays or solid state
outputs to shunt alarm contacts on the access door/gate preventing the
triggering of an alarm when an authorized access occurs.
The 921P EntryCheck™ is powered from a 12-24V AC or DC source. The
non-volatile EEPROM memory retains entry codes and programming when
power is removed. An internal jumper is provided to reset the master code.
The Main Relay has a 5 Amp capacity. The Auxiliary Relay has a 2 Amp
capacity. Two solid state outputs, capable of sinking 100 mA to common
are programmable for alarm shunting, or to signal forced entry, door ajar,
keypad lockout, request-to-exit, and keypad active conditions.
P:\INSTALLATION INST\Access Controls\INST-921\INST-921P.vsd Rev C 04-14 Page 1
INSTALLATION INSTRUCTIONS
921P EntryCheck
TM
801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 •
www.sdcsecurity.com • E-mail: [email protected]
SPECIFICATIONS
Mechanical
Keypad Dim:
3.00" W x 5.75" H x 1.375" D
(1.4375” wall projection)
Ext. Controller Dim: 7.75" W x 5.75" H x 3.70" D
Electrical
Input Voltage: 12/24 Volts AC or DC
Operating Current: 30 mA typical, 150 mA max
Output Ratings
Main Relay: Form “C” 5 Amps @ 28 Volts max
Auxiliary Relay: Form “C” 2 Amp @ 28 Volts max
Type: Solid state outputs (Outputs #3 & #4)
Short-to-common 100 mA @ 24 VDC maximum
Environmental
Temperature: -22°F to 149°F (-30°C to 65°C)
Humidity: 5% to 95% non-condensing
4 to 6 digit user codes
4 independent outputs
4 independent timers
2 Form C relay contacts
2 solid state open collector outputs
Program entry codes to activate one or
two relays
Disable input
Door sense input
Request-to-exit/enter input
Keypad tamper lockout
Timed anti-passback
Anti-tailgate
Two LED status indicators
Tactile key feel
Audible code entry verification
Control electronics separate from
keypad for added security.
12V or 24V, AC or DC operation
Keypad programmable
500 user codes
3 User Modes
PIN or Card
Card Only
Card and PIN