SDC S6100 SERIES REVERSIBLE PANIC/FIRE EXIT User Manual
Page 20
P:\INSTALLATION INST\Mechanical Hardware\INST-S6800.vsd Rev -
12/10 Page 8
2. Release push bar, Make sure both top and bottom latch bolts are FULLY extended
3. Check top latch bolt for deadlocking function.
Depress the deadlock plate by hand.
When the deadlock plate is depressed,
the latch bolts should be locked in the
extended position and unable to be pressed
down (figure 7-3).
4. Check device operation by depressing and releasing push bar several times to assure
correct final installation.
5. Hang door (with device installed) and repeat operation check with outside lever.
6. redo rod length adjustment if either top latch bolt is not held retracted or if the bottom
latch bolt does not clear the floor and bottom strike.
Figure 7-3
Top Latch
Bolt
Deadlock
Plate
.079"
.985"
1.831"
1.496"
2.441"
1.339"
1.417"
1.969"
2.598"
.472"
1.339"
.748"
1.732"
3.150"
4.134"
.236"
Figure 8-1
Figure 8-2
H. INSTALL TOP STRIKE
1. Prepare frame:
a. Cut out a square on the frame
for the top strike (figure 8-1).
b. Weld two 3mm thick mounting
plates on the frame (figure 8-2).
c. Drill holes and tap #10-24 threads
on the mounting plates.
2. Install the top strike on the mounting plates (figure 8-3) and secure with supplied screws (figure 8-4).
Figure 8-3
Figure 8-4