SDC R7500 HiTower SCHLAGE L9080 MORTISE LOCK User Manual
Security door controls
SECURITY DOOR CONTROLS
801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • Fax: (805) 494-8861
www.sdcsecurity.com • E-mail: [email protected]
P:\INSTALLATION INST\Electrified Lockset\INST-7500HI-R REV A 02-10 Page 1
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email [email protected]
For the door portion follow the enclosed mortise lock instructions.
For the frame portion (electric actuator) read these instructions carefully.
To insure a neat and easy installation of the electric actuator into
the frame back box when making long wire runs, the heavier
gauge wire can be terminated in a junction box above the door.
At this point a smaller gauge wire cable may be run from the
junction box to the frame electrical back box. This provides for
easier insertion of the electric actuator.
For proper operation, the voltage as indicated on the lock
solenoid must be at the lock location with the load on.
1. The wiring assignments are shown on the reverse side of
this page as well as on the electric actuator. The lock is
supplied with 6" wire leads and will require 10" leads from
the conduit.
2. Attach power supply leads to lock leads as shown. Wire
nuts are sufficient for these connections
3. Insert wires into the jamb carefully so they do not interfere
with proper positioning of the lock in the cut-out.
4. Insert lock and secure with screws provided.
5. With the electric actuator power on, check to see if the
levers are locked. On 7540 and 7550 models only the
outside lever should lock. The actuator is set for 1/8”
door clearance as shipped from the factory. If the clearance
between the door and the jamb is more or less than 1/8” the
following adjustment must be made (refer to Fig. E).
A. Loosen the allen screw in the plunger.
B. Remove plunger head.
C. Turn each adjustment screw equally in desired
direction. Counter-clockwise for wide gaps -
clockwise for narrow gaps.
IMPORTANT: ADJUSTMENT SCREWS MUST BE TURNED
EQUALLY TO OPERATE FREELY.
D. Replace plunger head and test lock. Lever should lock
when actuator is energized.
Strike Plate Dimensions
For Metal Frames: 4-7/8” x 1-1/4” x .0937"
ID Requirements
Standard Actuator: 12" x 2-1/2” x 2"
Fails Safe: Continuous duty – locked when energized
UL Listed: Electrically controlled single point locks or latches.
Electric Actuator
Solenoid points
down when
actuator is
used with:
SOURCE MODEL:
R Schlage
L9080
ADJUSTABLE
SCREWS MOVE
OUT FOR WIDE
DOOR GAP
ACTUATOR
PLUNGER
HEAD
Fig. E
PATENT #4634155 - #4641867
ELECTRICAL
BACK BOX
DOOR
FRAME
INSTALLATION INSTRUCTIONS
HiTower R7500, SCHLAGE L9080 MORTISE LOCK, SOURCE ZR (RETROFIT)
(REPLACES SDC 5000 SERIES)
®