SDC S6100 SERIES REVERSIBLE PANIC/FIRE EXIT User Manual
Page 3
P:\INSTALLATION INST\Mechanical Hardware\INST-S6100.vsd Rev -
12/10 Page 3
STOP LINE
Jamb
of Device
Strike
L
C
Strike
Site
Door
D. INSTALL STRIKE TO FRAME
1. Place strike over the drilled holes, and attach it to
the jamb or mullion with the supplied screws.
2. If installing with a vertical rod device for double
doors, and additional Double Door Strike must be
used in place of the regular strike provided.
E. IF CYLINDER IS INCLUDED WITH THE DEVICE
1. Drill one 1-3/16" diameter thru hole for the cylinder/bracket plate.
2. Insert cylinder and cylinder collar from outside of door.
3. Place bracket plate on inside of face of the door.
4. Put two cylinder mounting screws through the bracket plate and
into the cylinder.
5. Cut the cylinder mounting screws and tailpiece to the required door
thickness at break-off points, then fasten screws.
F. INSTALL OUTSIDE TRIM
Mark and drill holes for the outside trim (see trim instructions).
E. INSTALL DEVICE BODY
1. Remove chassis cover from latch assembly
and end cap from end cap bracket.
2. Place the device horizontally over the drilled holes and
attach with the supplied mounting screws. Bolt
device chassis to trim with sexbolts (if required).
3. Make sure cylinder or trim actuator shaft (tailpiece) can
insert into device cam concentrically (see device cam
at right).
4. Install end cap bracket on device, then screw to door.
5. Tighten all screws or bolts.
Device Cam
Insert Trim Actuator Shaft
Into device cam “+”.
Latch
Assembly
Outside face of door
Cylinder Collar
Rim Cylinder
Cylinder
Actuator shaft
(Tailpiece)
Inside face of door
Cylinder
bracket plate
Cylinder mounting
screws
Tailpiece projection
1/4”