beautypg.com

SDC S6100 SERIES REVERSIBLE PANIC/FIRE EXIT User Manual

Page 3

background image

P:\INSTALLATION INST\Mechanical Hardware\INST-S6100.vsd Rev -

12/10 Page 3

STOP LINE

Jamb

of Device

Strike

L

C

Strike

Site

Door

D. INSTALL STRIKE TO FRAME

1. Place strike over the drilled holes, and attach it to
the jamb or mullion with the supplied screws.
2. If installing with a vertical rod device for double
doors, and additional Double Door Strike must be
used in place of the regular strike provided.

E. IF CYLINDER IS INCLUDED WITH THE DEVICE

1. Drill one 1-3/16" diameter thru hole for the cylinder/bracket plate.
2. Insert cylinder and cylinder collar from outside of door.
3. Place bracket plate on inside of face of the door.
4. Put two cylinder mounting screws through the bracket plate and
into the cylinder.
5. Cut the cylinder mounting screws and tailpiece to the required door
thickness at break-off points, then fasten screws.

F. INSTALL OUTSIDE TRIM

Mark and drill holes for the outside trim (see trim instructions).

E. INSTALL DEVICE BODY

1. Remove chassis cover from latch assembly
and end cap from end cap bracket.
2. Place the device horizontally over the drilled holes and
attach with the supplied mounting screws. Bolt
device chassis to trim with sexbolts (if required).
3. Make sure cylinder or trim actuator shaft (tailpiece) can
insert into device cam concentrically (see device cam
at right).
4. Install end cap bracket on device, then screw to door.
5. Tighten all screws or bolts.

Device Cam

Insert Trim Actuator Shaft

Into device cam “+”.

Latch

Assembly

Outside face of door

Cylinder Collar

Rim Cylinder

Cylinder

Actuator shaft

(Tailpiece)

Inside face of door

Cylinder

bracket plate

Cylinder mounting

screws

Tailpiece projection

1/4”