SDC E6200 SERIES MAGNETIC LOCK User Manual
SDC For Home
801 Avenida Acaso, Camarillo, Ca. 93012
(805) 494-0622 • Fax: (805) 494-8861
www.sdcsecurity.com • E-mail: [email protected]
The E6200 Series magnetic lock is mounted to the underside of the header, on the stop side of the door.
P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E6200.vsd REV -
07-10 Page 1
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email [email protected]
INSTALLATION INSTRUCTIONS
E6200 SERIES MAGNETIC LOCK
Electrical Instructions:
Use properly fused U. L. Listed Power Supply
Do not install a diode in parallel with any magnetic lock. A diode
will cause a delay when releasing the door and residual magnetism
to occur.
Although SDC recommends the use of a DC power supply, a
transformer with an adjacent mounted full wave bridge rectifier
may be used. A significant drop will occur when using a full wave
bridge rectifier.
Any low voltage condition will cause erratic operation of the
optional board sensor.
When using a full wave bridge rectifier all access controls and/or
release contacts must be located between the EMlock and rectifier
to ensure quick release.
Electrical Specifications:
Dual Voltage
12 or 24VDC
Power Consumption
.250mA@12VDC
.125mA@24VDC
DS Door Status Sensor SPDT, 500mA@30VDC
LS Lock Status Sensor SPDT, 2A@30VDC
Mounting Screws
Armature
Frame
Outswing