beautypg.com

SDC LRPD2L LATCH SWITCH KIT-VERTICAL ROD PHI/STANLEY 2000 SERIES User Manual

Security door controls

background image

LRPD2L

INSTALLATION INSTRUCTIONS

LATCH SWITCH KIT-VERTICAL ROD

PHI/STANLEY 2000 SERIES

Remove head cover. Attach cable tie to device at existing tapped hole where shown, with supplied screw. Attach magnet at

existing thru hole where shown with supplied screw and nut. Route wires as shown. Re-attach head cover.

*

NOTE: Regardless of handing, the Latch Switch Kit is always attached to the “LHR” side of the device.

Any suggestions or comments to this instruction or product are welcome.

Please contact us through our website or email [email protected]

P:\INSTALLATION INST\SWITCH KITS\INST-LRPD2L.vsd REV -

01-12 Page 1

SECURITY DOOR CONTROLS

801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • Fax: (805) 494-8861
www.sdcsecurity.com • E-mail: [email protected]

Applications
Remote Latch Status Monitoring:
Retracting the latch by depressing the push
pad provides an output signal for local or
remote visual and audible annunciation
indicating forced entry or unauthorized
egress.

Access Control REX: When connected to
the Request-To-Exit input of a keypad,
card or biometric Access Controller,
depressing the pushpad and retracting the
latch actuates the Latch Status contact,
shunting the control access control alarm
to permit authorized egress and/or
releases the magnetic door lock for
uninhibited egress.

Magnetic Lock Release: Where Access
Controller with REX input is unavailable,
the N/C contact of the switch is wired in
series between the power supply and fail
safe magnetic lock. Depressing the exit
device pushpad retracts the latch, causing
the contact to open, thereby releasing the
magnetic lock for uninhibited egress.

Mantrap Logic: Provides N/O and N/C
contacts required for 2 or more
communicating doors for Interlock and
Mantrap applications.

HEAD

COVER

YEL – N/O

GRY – COM

ORG – N/C

200mA @ 30VAC RESISTIVE

CABLE

TIE

MAGENTIC

SENSOR

MAGNET