P:\INSTALLATION INST\Mechanical Hardware\INST-S6800.vsd Rev -

12/10 Page 3

A. PREPARE DOOR

1. Mark centerline of device by
drawing a line across the door.

2. Mark a backset line and 4 thru
holes for device chassis shown
on the template provided.

3. Prepare the door cut-outs by
using the template provided.

Figure 1-2

4. Cut out the top edge and bottom edge of the door, then weld two 5mm thick mounting plates
on both edges for Top and Bottom Latch Assemblies (figure 1-2).

5. Drill holes and use a #10-24 tap on the mounting plates on the top and bottom of door.

The centerline of the
device must be 40"
above the finished
floor. Bottom Door
gap MUST be 1/4”.

2-7/16"

of Device

L

C

Mark backset from edge of door

INSIDE FACE OF DOOR

Drill holes and
cut-outs on the
Device side ONLY

of Device

L

C

39

-3/

4”

See Trim Installation
Instructions for outside
face of door preparation.

Figure 1-1

1-3/4”

2-1/4”

7/8"

2-7/16”

1-19/32"

1-9/32"

1-5/32"

23/32"

1-11/16"

7/16"

7/8"

7/8"

Inside Face

of Door

1-17/32"