INSTALLATION INSTRUCTIONS LR100SGK-EM

ELECTRIC LATCH RETRACTION DEVICE KIT

SARGENT MODELS: 8600, 8700 & 8800

P:\INSTALLATION INST\SWITCH KIT\INST-LR100SGK-EM.vsd REV -

01-14 Page 1

Any suggestions or comments to this instruction or

product are welcome. Please contact us through

our website or email [email protected]

801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 •
www.sdcsecurity.com • E-mail: [email protected]

Remove the Head Assembly from the
device. Carefully run the Cable inside
the rail over the hinge brackets.
Attach the Bell Crank as shown. Re-
install the Head Assembly to the
device. Remove access cover and
attach the ELR assembly to the device
with the supplied screw.

Depress Latch

Retractor and
insert the Bell

Crank as

shown.

BELL

CRANK

Latch

Retractor

Run the cable through the ELR Clevis Block and
Cable Sleeve. Install the device to the door. Mount
the ELR assembly in the device by positioning the
assembly close to the edge of the rail. Use the
mounting tab from the exit device to secure the ELR to
the base. Once the assembly is secure then use a
7/64 drill bit to drill out the inserts and use the supplied
screws to fasten kit to the device and door.

Attach the ELR to the device
with the supplied screws.

CABLE
SLEEVE

CLEVIS
BLOCK

Carefully run the Cable inside the rail
over the hinge brackets.

ELECTRICAL DATA

24VDC @ 700/200mA

RED (+) BLK (-)

PATENT PENDING

Energize the ELR assembly, then pull the cable so that
it retracts the latch far enough to clear the strike. Hold
the cable in position and secure the set screw firmly on
the clevis block, so that the Cable Sleeve secures the
cable in block. Test operation and re-attach access
cover (NOTE: Access Cover can NOT go back on the
same way as it came off. It must be rotated 180
degrees).