beautypg.com

SDC LR100PDK ELECTRIC LATCH RETRACTION DEVICE KIT 5100 User Manual

SDC For Home

background image

INSTALLATION INSTRUCTIONS LR100PDK

ELECTRIC LATCH RETRACTION DEVICE KIT

PHI/STANLEY MODELS: 2101, 2201, 2400, 2600, 2801, 5100 & 5200

P:\INSTALLATION INST\ELR KITS\INST-LR100PDK.vsd REV H 04-14 Page 1

Any suggestions or comments to this instruction or

product are welcome. Please contact us through

our website or email [email protected]

801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 •
www.sdcsecurity.com • E-mail: [email protected]

RE-ASSEMBLE PUSHBAR,

HOUSING, COVER AND END

CAP BEING CAREFUL NOT

TO DAMAGE THE WIRES ON

THE E. L. R. ASSEMBLY.

ELECTRICAL DATA

24VDC @ 700/200mA

RED (+)

BLK (-)

PATENT PENDING

Carefully remove the End Cap, End Cover, Device Housing and Pushbar. If present
in device, remove dogging. Replace existing spring with new SDC supplied spring.
Attach L. R. Assembly to Exit Device.

PUSHBAR

DEVICE HOUSING

END CAP

END COVER

When installing in to vertical rod devices,

removal of the bottom rod is required for

proper operation of the Electric Latch

Retractor.

REPLACE EXISTING
SPRING WITH NEW
SPRING SUPPLIED

ELECTRIC LATCH
RETRACTION ASSEMBLY

ATTACH LINKAGE WHERE SHOWN.
USE 2 SUPPLIED SCREWS TO ATTACH
ELECTRIC LATCH RETRACTION
ASSEMBLY TO PHI EXIT DEVICE.

LINKAGE
LARGE END

TEMPORARILY REMOVE ELR
COVER TO INSTALL. AFTER ELR
IS INSTALLED, REPLACE COVER.