H. install covers – SDC S6100 SERIES REVERSIBLE PANIC/FIRE EXIT User Manual
Page 4
P:\INSTALLATION INST\Mechanical Hardware\INST-S6100.vsd Rev -
12/10 Page 4
H. INSTALL COVERS
NOTE: The Device bar has 3 different lengths;
Standard 3' Door Device = Approx 33"
Standard 3.5' Door Device = Approx 40"
Standard 4' Door Device = Approx 44"
The bar lengths of devices are pre-cut for 36", 42" and
48" wide door, no additional cutting is necessary.
If narrower door installation is needed, cut device at the
“A” location, to door width minus 4" to fit properly.
1. Test push bar operation before installing covers:
a. No Trim:
Latch bolt is retracted by push bar
inside.
b. With Trim: Latch bolt is retracted by push bar
inside, key or lever/knob outside.
c. Dogging:
See dogging description and chart
below.
2. Make sure and secure latch bolt engagement. Adjust
strike if required.
3. Install chassis cover on chassis.
4. Install end cap.
Note: For increasing the life of this device,
dogging device during high traffic
period of the day (Panic device only).
Dogging Wrench
(Allen Key)
Dogging:
Depress push bar,
Insert dogging wrench
and turn clockwise 35 degrees.
Depress
push bar
The push bar will remain
depressed and the latch will
remain retracted
Release Dogging:
Depress push bar,
Insert dogging wrench and
turn counter-clockwise 35 degrees.
Depress
push bar
The push bar will return to up
position and the latch will project
to lock the door.
Latch
Assembly
Mark mounting holes
through End Cap
Bracket
after device is level
A