beautypg.com

SDC S6100 SERIES REVERSIBLE PANIC/FIRE EXIT User Manual

Page 19

background image

P:\INSTALLATION INST\Mechanical Hardware\INST-S6800.vsd Rev -

12/10 Page 7

3. Cut the length if required:

a. The device length is pre-cut for use on 36", 42" or 48" wide doors, no additional cutting is
necessary. If narrow door installation is required, cut device at section “A” to door width
minus 2" for proper fit.
b. Remove device from door, remove end cap and end cap bracket and cut where required.

NOTE: Device must be cut flat with all burrs removed for end cap to fit properly.

4. Mount device horizontally via the drilled holes and secure with supplied mounting hardware.
Attach device to trim or sexbolt (if applicable).
5. Install end cap bracket to device and attach to door with hardware supplied. Attach end cap.

Figure 6-2

G. TEST OPERATION AND HANG DOOR.

1. Depress push bar. Top latch bolt should be retracted as shown (figure 7-1) and
bottom latch clears floor and bottom strike (figure 7-2).

Figure 7-1

BOTTOM

LATCH BOLT

(Clears floor

and strike).

Figure 7-2

A