beautypg.com

SDC LR100SGK ELECTRIC LATCH RETRACTION DEVICE KIT SARGENT 8600, 8700 & 8800 User Manual

SDC For Home

background image

INSTALLATION INSTRUCTIONS LR100SGK

ELECTRIC LATCH RETRACTION DEVICE KIT

SARGENT MODELS: 8600, 8700 & 8800

P:\INSTALLATION INST\SWITCH KIT\INST-LR100SGK.vsd REV C 10-13 Page 1

Any suggestions or comments to this instruction or

product are welcome. Please contact us through

our website or email [email protected]

801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 •
www.sdcsecurity.com • E-mail: [email protected]

Remove the Head Assembly from the
device. Carefully run the Cable inside
the rail over the hinge brackets.
Attach the Bell Crank as shown. Re-
install the Head Assembly to the
device. Remove access cover and
attach the ELR assembly to the device
with the supplied screw.

Depress Latch

Retractor and
insert the Bell

Crank as

shown.

BELL

CRANK

Latch

Retractor

Attach the ELR to the device with
the supplied screw.

CABLE
SLEEVE

Template must be used for 42" & 48" bars.
Slide template into device until it stops
against the rubber pad.
Mark hole location and drill 5/32" diameter
hole thru the device extrusion.

TE

MP

-LR

10

0S

GK

FO

R

42

" &

48

" B

AR

S

Run the cable through the ELR Clevis Block and Cable
Sleeve. Install the device to the door. Energize the
ELR assembly, then pull the cable so that it retracts the
latch far enough to clear the strike. Hold the cable in
position and secure the set screw firmly on the clevis
block, so that the Cable Sleeve secures the cable in
block. Test operation and re-attach access cover
(NOTE: Access Cover can NOT go back on the same
way as it came off. It must be rotated 180 degrees).

CLEVIS
BLOCK

Carefully run the Cable inside the rail
over the hinge brackets.

ELECTRICAL DATA

24VDC @ 700/100mA

RED (+) BLK (-)

PATENT PENDING