INSTALLATION INSTRUCTIONS

350 NARROW LIINE EMLOCK

Electrical Instructions:

Use properly fused U. L. Listed Power Supply

Do not install a diode in parallel with any magnetic lock. A diode
will cause a delay when releasing the door and residual magnetism
to occur.

Access controls and/or release contacts must be located in series
with the positive (+) power lead of the EmLock.

Any low voltage condition will cause erratic operation of the
optional board sensor.

Although SDC recommends the use of a Regulated DC power supply, a
transformer with an adjacent mounted full wave bridge rectifier
may be used. A significant voltage drop will occur when using a full wave
bridge rectifier.

Electrical Specifications:

Dual Voltage

12 or 24VDC

Power Consumption

540mA@12VDC
300mA@24VDC

DS Door Status Sensor SPDT, 250mA@30VDC
LS Lock Status Sensor SPDT, 2A@30VDC