INSTALLATION INSTRUCTIONS
350 NARROW LIINE EMLOCK
Electrical Instructions:
Use properly fused U. L. Listed Power Supply
Do not install a diode in parallel with any magnetic lock. A diode
will cause a delay when releasing the door and residual magnetism
to occur.
Access controls and/or release contacts must be located in series
with the positive (+) power lead of the EmLock.
Any low voltage condition will cause erratic operation of the
optional board sensor.
Although SDC recommends the use of a Regulated DC power supply, a
transformer with an adjacent mounted full wave bridge rectifier
may be used. A significant voltage drop will occur when using a full wave
bridge rectifier.
Electrical Specifications:
Dual Voltage
12 or 24VDC
Power Consumption
540mA@12VDC
300mA@24VDC
DS Door Status Sensor SPDT, 250mA@30VDC
LS Lock Status Sensor SPDT, 2A@30VDC
Outswing
Quick Mount
Interlocking
Mounting Assembly
Mounting Screws
Armature
Interlocking
Mounting Plate
Frame
801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 •
www.sdcsecurity.com • E-mail: [email protected]
Retrofits Discontinued Locknetics 350+
Provides Superior Architectural Appearance
Supplied Mounting Hardware
PATENT NO. 5,376.910