System bus (can) for lenze plc devices, Lenzecandsxdrv.lib function library – Lenze DDS System bus CAN for PLC User Manual
Page 171

System bus (CAN) for Lenze PLC devices
LenzeCanDSxDrv.lib function library
11.11
L_CanDSxCloseNodeGuarding − deactivating the "Node Guarding"
11−15
L
PLC−Systembus EN 2.0
11.11
L_CanDSxCloseNodeGuarding − deactivating the "Node
Guarding"
Function
By means of this function, the "Node Guarding" monitoring mechanism of the CanDSx driver is
deactivated again.
·
For the deactivation the transfer parameter bClose has to be set to TRUE.
Declaration
BOOL
L_CanDSxCloseNodeGuarding (bClose);
Transfer parameters
Data type
Information/possible settings
bClose
Bool
Deactivating the "Node Guarding" monitoring mechanism
TRUE The "Node Guarding" monitoring mechanism of the CanDSx driver is deactivated.
Return value
Data type
Value/meaning
Bool
Status
TRUE The "Node Guarding" monitoring mechanism of the CanDSx driver has been
deactivated.
FALSE The "Node Guarding" monitoring mechanism of the CanDSx driver has not been
deactivated.
·
Remedy: function call via transfer parameter bClose = TRUE.
Example
Calling the function in ST:
bReturnCloseNodeGuarding :=
L_CanDSxCloseNodeGuarding(bClose:=TRUE);