Basic Setting The Camera Model, Baud Rate, and Address must also match the configuration
within your camera. Refer to the User Manual of your PTZ camera for configuring the camera’s
Protocol, Baud Rate, and Address. We recommend using Pelco-P Protocol - 9600 Baud Rate, or
Pelco-D Protocol - 2400 Baud Rate.
COM Port
Fig. 49. Device Manager window
The COM Port must be the port that your USB to Serial TRP-C08 is currently using. (Check the
Device Manager within Windows to verify which COM Port is being used.)
► Note If the current COM Port being used by the TRP-C08 is COM5 or above,
you will need to manually set the COM Port to COM1-COM4. Go to Port
Settings and click on the Advanced button. At the bottom of the window,
click on the drop-down button Com Port Number. Select an available
port between 1 and 4. If these ports are unavailable, contact your system
provider.
Advanced Setting You may adjust the Pan, Tilt, Zoom, and Auto Pan speeds.
Patrol Group If you have multiple pre-set positions stored within the software, this will allow you