beautypg.com

3 software set up – EZWatch Pro 4.0 User Manual

Page 112

background image

Page |

111

“How To” Guides

Following the instructions included with the camera set the Protocol to “Pelco D”, set the baud rate

to 2400, and set the camera’s two digit address. When addressing the camera, make the camera’s

address the same as the video input on the DVR. For example, for video input 1 address the camera 01.

Connect the two-wire communication wire to the TX+ and TX- terminals on the camera, as shown in

Fig. 147

.

DVR

Twisted 2-Wire Communications Line

RS-485

Camera

Camera

Camera

Camera

RS-485

RS-485

RS-485

To 16 Cameras

or 3000 feet

Netcom

Module

Fig. 147. Connecting cameras to twisted two-wire

communications lines

4.5.3 Software Set Up

Step 1

Go to Start > All Programs > EZWatch Pro 4.0 > Main Console.

Step 2

Click the Config button on the Main Console. Then click on the PTZ Config tab at the top

of the window.

Basic Setting

Advanced Setting

Fig. 148. PTZ Config tab in Setting window