Configuration by computer – 2N Lift8 v1.6.0 User Manual
Page 124
124
1105
SIP server
Set the IP address for
connection to the
counterparty (PBX,
operator). **
1106
User
Set the user name for
connection to the
counterparty (PBX,
operator). **
1107
Password
Set the password for
connection to the
counterparty (PBX,
operator). **
1108
Enable
in-band
DTMF
detector
0–1
0
1109
SIP server
port
1–65535
5060
Set the PBX (operator) port
via which the SIP Proxy
communicates with the
terminals connected. **
1220
Camera type
0–2
1
not implemented
1221
Resolution
0–4
2
not implemented
1222
Compression
ratio
1–100
60
not implemented
1230
Client
enabled
0–1
0
not implemented
1231
Server IP
addres
empty
not implemented
1232
Server port
1–65535
7008
not implemented
1234
Password
empty
not implemented
* This parameter can only be configured via the voice menu (incoming call to
or via
L8
the machine roo
m audio unit).
** This parameter can only be configured via the
.
2N Service Tool
®
Configuration by Computer
Install the
to configure
connected to a PC via the USB or via the
2N Service Tool
®
L8
Internet using the
IP address (UMTS version only). You can also upgrade of the
L8
firmware.
Install and launch the
from the included CD for more details. Find
2N Service Tool
®
the current
version at
2N Service Tool
®
Caution
Parameters 1003 and 1004 are used for username and password
configuration for verification at the provider's. Most providers do not use
any verification. If the your provider requires verification, it must give you
the necessary access data.