❑ Electrical Installation
86
FoamLogix 3.3 / 5.0 / 6.5 Installer / Operations Manual
p/n: 029-0021-68-0
CAUTION ! - continued
❑
Before connecting the cables, inspect the O-ring seal in the female
connector. If the seal washer is missing or damaged, water can
enter the connector causing corrosio, resulting in possible system
failure.
❑
The ground strap must be a minimum of 1-1/4” (32mm) wide and no
longer than 18” (457mm).
A longer ground strap must be wider or a double thickness strap
must be used.
Make sure the ground strap is attached to the chassis frame.
Grounding to the body IS NOT acceptable.
❑
Always disconnect the power cable, ground straps, electrical wires
and cables from the control unit or other Hale FoamLogix equip-
ment before electric arc welding at any point on the apparatus.
Failure to do so could result in a power surge through the unit that
could cause irreparable damage.
❑
There are no user serviceable parts inside Hale FoamLogix system
electrical/electronic components. Opening of these components
(motor distribution box or control unit) voids the warranty.