Hale FoamLogix 6.5 User Manual
Page 25

25
FoamLogix 3.3 / 5.0 / 6.5 Installer / Operations Manual
p/n: 029-0021-68-0
Intr oduction
❑
Rated Foam Concentrate Output - continued
Model 6.5 ...................................................................... 6.5 GPM (25 LPM)
Maximum System Operating Pressure
Model 3.3 ....................................................................... 350 PSI (24 BAR)
Model 5.0 ....................................................................... 200 PSI (14 BAR)
Model 6.5 ....................................................................... 200 PSI (14 BAR)
Maximum Operating Temperature.................................... 160° F (71° C)
Pump Motor
Standard - Models 3.3 and 5.0 ........................... 3/4 HP (0.6 kW), 12 VDC
Standard - Model 6.5 .......................................1-1/4 HP (0.9 kW), 24 VDC
Optional ..............................................................3/4 HP (0.6 kW), 24 VDC
Operating Ampere Draw...... 30 AMPS at 12 VDC (15 AMPS at 24 VDC)
Maximum Ampere Draw ...... 60 AMPS at 12 VDC (30 AMPS at 24 VDC)
Figure 2-2: Foam Pump Installation Envelope Dimensions
(Configured for use with MDT II, MST or No Tank Selection Options.)