beautypg.com

Festo Модуль перемещения HSP User Manual

Page 59

background image

HSP−...−AP/A S

Festo HSP−...−AP/AS 0508a English

59

Type

HSP−25−...

HSP−16−...

HSP−12−...

Lubrication

Cross guide with service life lubrication,
re−lubrication recommended after 10 million
strokes.

End position adjustment

Adjusting screws in the y−direction
Stop screws in the z−direction

End position cushioning with shock absorber

YSRW−5−8

YSRW−7−10

YSRW−8−14

Permitted shock absorber energy
E

max

[Nm]

E

hmax

[kNm]

1
10

2
15

3
21

Min. permitted pulse time [s]
Pulse time t

t

= positioning time t + dwell time t

e

(definition see chapter 7)

0.6

0.8

1

Stroke ranges

y−stroke [mm]

52...68

90...110

130...170

z−stroke [mm]

20...30

35...50

50...70

Max. permitted loading values of the cross
guide

Dynamic torque M

per

[Nm]

*)

with vertical operation and observation of the

1.1

2.4

3.2

with vertical operation and observation of the
maximum work load

M

x

M

zul

)

M

y

M

zul

)

M

z

M

zul

v 1

Static torque M

Oper

[Nm]

*)

with vertical operation

5

10

15

with vertical operation
for press−fit and joining procedures without
dynamic loading

Mo

x

Mo

zul

)

Mo

y

Mo

zul

)

Mo

z

Mo

zul

v 1

*)

The torques refer to the centre of the cross guide.