S
Check the cushioning elements and spring clamping elements (type designaĆ
tion see Accessories") for the following signs of wear:
Test
Spring clamping
element
1
Shock absorber
2
(...−AP)
Rubber buffer
2
(...−AS)
Test cycle
Every 2 million strokes (approx.Ăevery 2 months)
1)
Sign of wear
Play of the vertical
guide rail in the end
positions in a
horizontal direction
Oil leakage; hard
knocking; stop plunger
remains in the
retracted end position
or moves away from it
only hesitantly.
Hard knocking
2)
Replacement cycle
After 5 million cycles
Every 10 million strokes (approx 1 year)
1)
1)
At 0.5 Hz in dual operation mode.
2
) The rubber buffers in the fixed stops are only to reduce noise.
S
Check to see if more frequent tests are required. This may be the case with:
ć higher temperatures
ć excessive dirt
ć solvent liquids or fumes.
Please note
If the load changes, repeat the test taking the modified work load into
consideration.
Ĉ End position adjustment (chapter Fitting")
Ĉ Setting the positioning speed (chapter Commissioning")
Please note
HSP−...−A S with an electromotor:
Moving to the fixed stop (Ă
2 in fig. 1) generates sudden loadings in the drive
chain. This can lead e.g. to gear damage.
S Move to the fixed stops only with low energy or use a drive chain which can
withstand sudden loadings. The rubber buffers in the fixed stops are only to