Festo Модуль перемещения HSP User Manual
Page 49
HSP−...−AP/A S
Festo HSP−...−AP/AS 0508a English
49
Test run
1. Tighten the two upstream one−way flow
control valves
ć at first completely
ć then loosen approximately one turn.
2. Make sure that the operating conditions
lie within the permitted ranges.
Please note
The permitted kinetic impact force at the
end stop applies for certain mass−speed
combinations. It must not be exceeded.
S Make sure that the permitted values for
the positioning time as a factor of the
work load are observed (chapter
Characteristic curves").
3. During the test run check:
ć that the proximity switches are functioning correctly
ć that the work load is held safely
ć the positioning time as a factor of the work load
ć the adjustment of the end positions.
4. When adjusting the end positions, observe the instructions in the chapter
Fitting."
Warning
Sudden movements of the actuators when they are under pressure during the
setting of the
y−stroke can cause injuries and loose link parts can damage the
HSP−...Ă.
S Exhaust the drive before you loosen the fastening screws of the link parts.
S After setting the y−stroke: Make sure that the fastening screws of the link
parts are screwed tight.
In this way you will avoid injury to human beings and damage to the device.
Fig. 20
Fig. 21