Fitting: pneumatic components – Festo Модуль перемещения HSP User Manual
Page 45
HSP−...−AP/A S
Festo HSP−...−AP/AS 0508a English
45
Fitting: Pneumatic components
Connecting the drive for type HSP−...−AP:
S
Use one−way flow control valves of type
GRLA−... for setting the swivel speed. The
speed will be reduced by the throttling of
the exhaust air.
S
Screw in both one−way flow control valves
on the drive.
S
Connect the tubing of the drive.
Connecting the add−on components:
Installation kit MKRP−.. (see chapter Accessories") enables the tubing and cables
to be grouped together in a flexible installation tube. The installation tube is fasĆ
tened to the cross guide with the support, and e.g. to the sub−base or the strucĆ
ture with the adapter bracket. The installation tube may be filled to max. 70 %.
Make sure that the moving pneumatic tubing
and electric cables are laid correctly (example
Fig. 18):
S
Lay the cables and tubing upwards along
the vertical guide rail.
S
Fasten the cables and tubing with cable
binders
ć on the support of the universal adapter
(A) or pass them through the two cable
channels of the universal adapter (B).
ć on the cable binder support (C) on the
cross guide.
S
Pass the cables and tubing through the
holes in the sub−base (E) or use protective
tubing (D).
Fig. 17
Fig. 18
(A)
(B)
(C)
(D)
(E)