beautypg.com

Fitting: pneumatic components – Festo Модуль перемещения HSP User Manual

Page 45

background image

HSP−...−AP/A S

Festo HSP−...−AP/AS 0508a English

45

Fitting: Pneumatic components

Connecting the drive for type HSP−...−AP:

S

Use one−way flow control valves of type
GRLA−... for setting the swivel speed. The
speed will be reduced by the throttling of
the exhaust air.

S

Screw in both one−way flow control valves
on the drive.

S

Connect the tubing of the drive.

Connecting the add−on components:

Installation kit MKRP−.. (see chapter Accessories") enables the tubing and cables
to be grouped together in a flexible installation tube. The installation tube is fasĆ
tened to the cross guide with the support, and e.g. to the sub−base or the strucĆ
ture with the adapter bracket. The installation tube may be filled to max. 70 %.

Make sure that the moving pneumatic tubing
and electric cables are laid correctly (example
Fig. 18):

S

Lay the cables and tubing upwards along
the vertical guide rail.

S

Fasten the cables and tubing with cable
binders

ć on the support of the universal adapter

(A) or pass them through the two cable
channels of the universal adapter (B).

ć on the cable binder support (C) on the

cross guide.

S

Pass the cables and tubing through the
holes in the sub−base (E) or use protective
tubing (D).

Fig. 17

Fig. 18

(A)

(B)

(C)

(D)

(E)