7 commissioning, Complete system, Individual unit – Festo Модуль перемещения HSP User Manual
Page 47: 7commissioning
HSP−...−AP/A S
Festo HSP−...−AP/AS 0508a English
47
7
Commissioning
Complete system
S
Slowly pressurize the complete system. This will prevent uncontrolled
movements from occurring. For slow start−up pressurization, use start−up valve
type HEL−... orĂHEM−...Ă.
S
Make sure that the conditions of use for the setting procedure are identical
with those in continuous operation. Otherwise there is a danger of the
handling module becoming overloaded.
Individual unit
Warning
S Make sure that:
Ĉ nobody can place his/her hand in the positioning range of the handling
module
Ĉ there are no objects in the path of the moveable mass
Ĉ there is no tubing in the path.
Protect the area e.g. by means of a cover or screen.
Please note
HSP−...−AP:
S Handle the shock absorbers with care so that the thread, the piston rod and
the outer cylinder are not damaged.
S Make sure that the shock absorbers are screwed in completely and locked
(asĂsupplied from the factory). If the shock absorbers are not screwed in
completely, the cushioning effect will be considerably reduced (reduced
cushioning stroke).
Please note
HSP−...−A S with an electromotor:
Moving to the fixed stop (Ă
2 in fig. 1) generates sudden loadings in the drive
chain. This can lead e.g. to gear damage.
S Carry out reference travel against the fixed stops only with low energy. The
rubber buffers in the fixed stops are only to reduce noise.