beautypg.com

Fitting: electric components – Festo Модуль перемещения HSP User Manual

Page 46

background image

HSP−...−AP/A S

Festo HSP−...−AP/AS 0508a English

46

Fitting: Electric components

Use proximity switches SME/SMT−8 for
scanning the end positions:

1. Remove the protective cover of the

handling module.

2. Make sure that the shock absorbers are

screwed in completely (only type ...−AP; as
supplied from the factory).

3. Push the proximity switch into the groove

of the sensor rail (A).

The electric proximity switches are trigĆ
gered by magnets in the stop screws (B).

4. Fasten the proximity switches in the end

positions. Subsequent adjustment of the
shock absorbers is not necessary.

Please note
The cables of the proximity switches must not lie in the working range of the
handling module.

S Clamp the cables in the groove of the side plates (D) and the sub−base.

S Secure the cables with the aid of the cover profile (C) of the installation kit

(cut to size).

S Paass the cables back through the through hole in the sub−base (E).

Fig. 19

(A)

(B)

(D)

(E)

(C)