beautypg.com

Fitting: mechanical components – Festo Модуль перемещения HSP User Manual

Page 39

background image

HSP−...−AP/A S

Festo HSP−...−AP/AS 0508a English

39

Fitting: Mechanical components

The HSP−... is supplied ready for fitting.

S

If necessary, remove the protective cover before fitting.

S

Fit first the add−on components and, in the case of the HSP−...−AS, the external
drive or after fastening make sure that there is sufficient free space for fitting
the components.

S

Make sure that the fastening surface can support the weight of the HSP−...Ă.

S

Fit the HSP−... only onto a flat fixed surface.

Select one of the following fastening methods:

ć

Direct fastening via 4 through holes in the sub−base

[mm]

HSP−12

HSP−16

HSP−24

H1

40

20

40

H2

40±0.2

100±0.2

100±0.2

@ D1

6.3

6.3

6.3

L1

200±0.6

280±0.6

370±0.6

ć

Fastening via the side plates
(user−specific hole pattern).

ć

Fastening on the rear of the sub−base with

ć sliding blocks type HMBN−5−M5

(Fig. 8) or

ć fastening kit type HMBK−ND and

connecting bracket type HMBV−ND
(example: Fig. 9).

Fig. 7

D1

L1

H2

H1

Fig. 8