beautypg.com

FUJITSU CentricStor V3.1D User Manual

Page 508

background image

508

U41117-J-Z125-7-76

Message lines

Explanation of console messages

Response
Check the ambient temperature and the fan situation. Notify maintenance staff iff no con-
nection to increased ambient temperatures or fan faults could be determined and this mes-
sage continues to appear.

SXSM058

sma#: Fatal general memory error; Module# =

ALERT
SXSM059

sma#: Recoverable general memory error; Module# =

ALERT
SXSM060

sma#: Recoverable ECC memory error; Module# =

ALERT
SXSM061

sma#: Recoverable CRC memory error; Module# =

ALERT
SXSM062

sma#: Fatal CRC memory error; Module# =

ALERT

Meaning
An internal error has occurred in memory module .

Response
Notify maintenance staff iff the message continues to appear.

SXSM063

sma#: Recoverable thermal memory event occurred; Module# =

ALERT
SXSM064

sma#: Fatal thermal memory error; Module# =

ALERT

Meaning
High temperatures were detected in memory module . The increase in the memory
temperature can, for example, be caused by a fan which is no longer fully operational (e.g.
if a fan prefailure has occurred).

Response
Check the ambient temperature and the fan situation. Notify maintenance staff iff no con-
nection to increased ambient temperatures or fan faults could be determined and this mes-
sage continues to appear.

SXSM065

sma#: Predictive memory error without spare memory; Module# =

ALERT

Meaning
A large number of internal recoverable errors have occurred in memory module . This
could result in a failure of the memory module.

Response
Notify maintenance staff.