FUJITSU CentricStor V3.1D User Manual
Page 508
508
U41117-J-Z125-7-76
Message lines
Explanation of console messages
Response
Check the ambient temperature and the fan situation. Notify maintenance staff iff no con-
nection to increased ambient temperatures or fan faults could be determined and this mes-
sage continues to appear.
SXSM058
sma#: Fatal general memory error; Module# =
ALERT
SXSM059
sma#: Recoverable general memory error; Module# =
ALERT
SXSM060
sma#: Recoverable ECC memory error; Module# =
ALERT
SXSM061
sma#: Recoverable CRC memory error; Module# =
ALERT
SXSM062
sma#: Fatal CRC memory error; Module# =
ALERT
Meaning
An internal error has occurred in memory module
Response
Notify maintenance staff iff the message continues to appear.
SXSM063
sma#: Recoverable thermal memory event occurred; Module# =
ALERT
SXSM064
sma#: Fatal thermal memory error; Module# =
ALERT
Meaning
High temperatures were detected in memory module
temperature can, for example, be caused by a fan which is no longer fully operational (e.g.
if a fan prefailure has occurred).
Response
Check the ambient temperature and the fan situation. Notify maintenance staff iff no con-
nection to increased ambient temperatures or fan faults could be determined and this mes-
sage continues to appear.
SXSM065
sma#: Predictive memory error without spare memory; Module# =
ALERT
Meaning
A large number of internal recoverable errors have occurred in memory module
could result in a failure of the memory module.
Response
Notify maintenance staff.