FUJITSU CentricStor V3.1D User Manual
Page 493

U41117-J-Z125-7-76
493
Explanation of console messages
Message lines
SXRP019
RPLM(#19): NOTICE: job canceled on PDS
Meaning
The PLS or the PDS could not execute a job because of a timeout.
Describes the command in which the timeout occurred.
For the PLS:
PLS_INSPECT
MOUNT
UMOUNT
For the PDS:
PDS_INSPECT
RDIR
INIT
UNLOA
The command is extended by the suffix _SENT_TIMECHECK.
After the RPLM has started, the commands PLS_INSPECT, UMOUNT and UNLOAD
can be preceded by 'INITIAL_' in the initialization phase. This occurs if a PV
was mounted in a PDS.
Response
The RPLM repeats the command automatically. If the message appears frequently, check
the device and/or the communication path. Notify maintenance staff if necessary.
SXRP022
RPLM(#22): ERROR: PLS reports VSN_NOEXIST on PDS
Meaning
The robot does not recognize the physical volume
Response
This may be temporary. You should nevertheless check whether the relevant tape cartridge
is known to the robot. Notify maintenance staff if necessary.
SXRP027
RPLM(#27): ALERT: Number of LVs over maximum
Meaning
The number of logical volumes is above the permitted maximum.
Response
Correct the configuration or remove some logical volumes with the command
plmcmd dele -v
.
SXRP028
RPLM(#28): NOTICE: Number of LVs under maximum again
Meaning
The number of logical volumes is again below the permitted maximum.