Sxcm... (chim), 3 sxcm... (chim) – FUJITSU CentricStor V3.1D User Manual
Page 449

U41117-J-Z125-7-76
449
Explanation of console messages
Message lines
SXCH009
ESCON-adaptor
ALERT
Meaning
A test of the internal data paths on the ESCON board (PCEAS/PCEAT) which runs during
the startup phase and idle times returned an error.
Response
Replace the ESCON board.
SXCH010
ESCON-adaptor
ALERT
Meaning
During a read access the data was corrupted when it was transferred from the SINIX me-
mory to the ESCON channel.
Response
Replace the ESCON board.
SXCH011
ESCON-adaptor
ALERT
Meaning
During a write access the data was corrupted when it was transferred from the ESCON
channel to the SINIX memory.
Response
Replace the ESCON board.
9.2.3
SXCM... (CHIM)
SXCM001
chim1 (sadm9): SCSI-Bus reset
None
This message is part of a message complex (see the