beautypg.com

FUJITSU CentricStor V3.1D User Manual

Page 466

background image

466

U41117-J-Z125-7-76

Message lines

Explanation of console messages

SXPL003

PLM(#3): ALERT: on not reachable

Meaning
It was not possible to send a message to the PDS on the host .

Response
Check whether the PDS and/or host are running and whether the TCP/IP connection is
okay. If the corresponding IDP is running but the connection is not working, check the cables
and the hubs. Notify maintenance staff if necessary.

SXPL004

PLM(#4): NOTICE: on reachable again

Meaning
The PDS can again be reached.

SXPL005

PLM(#5): CRITICAL: Physical Library Server not reachable

Meaning
It was not possible to send a message to the PLS.

Response
Check whether the PLS is functioning.

SXPL006

PLM(#6): NOTICE: Physical Library Server reachable again

Meaning
It was again possible to send a message to the PLS.

SXPL007

PLM(#7): ALERT: VLM not reachable

Meaning
It was not possible to send a message to the VLM.

Response
Check whether the VLM is functioning (normally the VLM and PLM are running on the same
host).

SXPL008

PLM(#8): WARNING: hard minimum of free PVs () of PVG , TL
reached

Meaning
There are almost no more free tapes. The reserve of free cartridges created during the last
“soft configuration” was not large enough. Only tapes are available. Reorganization
is performed and is given high priority.

Response
If the reduced throughput is currently causing problems, mount new cartridges.
In the long term: check the settings that control reorganization by means of the GXCC
function “Physical Volume Groups” (see

page 181

).